BNA1000 Series Modular Vector Network Analyzer

Overview

BNA1000 Series

formerly known as BN900

Series pricing:

BNA1000 - 2P8G5 (formerly known as BN900-285)- USD 14.299.00

BNA1000 - 4P6G5
(formerly known as BN900-465) - USD 18,699.00

BNA1000 - 4P8G5
(formerly known as BN900-485) - USD 20.899.00

The BNA1000 Series Vector Network Analyzer greatly assists engineers in their work by providing advanced RF testing capabilities. Its wide frequency range, high dynamic range, low trace noise, and quick measurement speed deliver accurate results for tasks like research and development. The VNA's effective directivity and compact size make it convenient for on-site measurements.The open interface allows engineers to customize the instrument for specific projects, promoting innovation. Supporting the VISA protocol ensures easy integration into existing systems, saving time in workflow. With professional-level performance at a cost-effective price, the BN900 is a valuable tool for engineers in various fields, helping them achieve accurate measurements efficiently and contributing to overall productivity.

Modular Vector Network Analyzer

Overview

Resources

Frequency range
300KHz-6.5GHz/8.5GHz
Output Power Range
-50dBm to +10dBm
Measurement parameters
S11 to S44
Measurement point per sweep
2 to 20001
Dynamic Range
>125dB @ IFBW=10Hz,typ. 130dB
Low trace noise
2mdB rms @ IFBW=3 kHz
Measurement speed
42µs/point @ IFBW=500kHz
Support
Standard VISA Protocol
Telecommunications
  • Testing and optimizing the performance of antennas, filters, and amplifiers in communication networks. Ensuring the efficiency of cellular base station antennas to enhance signal coverage and quality.
Energy
  • Analyzing and optimizing RF components in wireless power transfer systems and smart grids. Ensuring the efficiency of wireless charging systems for electric vehicles.
Aerospace and Defence
  • Verifying the functionality of radar systems, antennas, and communication devices in military and aerospace applications. Testing the radar cross-section of an aircraft using a VNA to optimize stealth capabilities.
Research and Academia
  • Conducting experiments and research in RF and microwave engineering.Investigating the characteristics of novel RF materials for use in communication systems. Courseware Solutions
Medical Devices
  • Analyzing and designing RF components in medical devices such as MRI machines and wireless medical sensors. Ensuring the accuracy and reliability of RF components in a medical imaging device.
Manufacturing Quality Control
  • Ensuring the quality and performance of RF components during the manufacturing process. Verifying the specifications of RF filters produced in a manufacturing facility.
Automotive
  • Testing and optimizing the performance of RF components in automotive communication systems and sensors. Analyzing the signal integrity of radar sensors for collision avoidance systems.
Internet of Things (IoT)
  • Analyzing and optimizing the RF performance of devices in IoT networks. Testing the communication range and reliability of sensors in a smart home system.
Consumer Electronics
  • Verifying the performance of RF components in devices like smartphones, Wi-Fi routers, and Bluetooth devices. Optimizing the antenna design in a smartphone to ensure reliable wireless connectivity.
Key facts
Frequency range
300KHz-6.5GHz/8.5GHz
Output Power Range
-50dBm to +10dBm
Measurement parameters
S11 to S44
Measurement point per sweep
2 to 20001
Dynamic Range
>125dB @ IFBW=10Hz,typ. 130dB
Low trace noise
2mdB rms @ IFBW=3 kHz
Measurement speed
42µs/point @ IFBW=500kHz
Support
Standard VISA Protocol
Control elements
Features
  • The BNA1000 Series is a modular vector network analyzer with 4 test ports and a frequency range of 300kHz to 6.5/8.5GHz.
  • It has a dynamic range of up to 130 dB and an effective directivity of 38-49 dB.
  • The instrument has a measurement accuracy of +/- 0.2 dB/2° for transmission measurements and +/- 0.4 dB/3° for reflection measurements.
  • It has a fast measurement time of 42μs per point and a trace noise of 2mdB rms.
  • The instrument is equipped with various external ports for trigger input, reference input, and reference output.
  • It has a working temperature range of +5°C to +40°C and a storage temperature range of -20°C to +60°C.
  • The system calibration interval is three years, and the instrument is available with various optional calibration modules, RF cables, and other functions.
Benefits
  • A versatile measurement range of 300kHz to 6.5/8.5GHz allows for a wide range of applications, including testing of RF/microwave devices and components such as filters, amplifiers, antennas, and cables.
  • Four N-type female test ports enable multiport testing and simultaneous measurement of S-parameters for up to four devices.
  • A high impedance of 50Ω provides accurate and reliable measurements for a variety of devices.
  • A high-frequency accuracy of ±5ppm and frequency resolution of 1Hz ensure precise and accurate measurements, even at high frequencies.
  • A large number of measurement points (2-20,001) and measurement bandwidth (1Hz to 2MHz) allow for a detailed analysis of device performance.
  • A high dynamic range (112 dB to 125 dB) ensures accurate measurement of weak signals and suppression of strong signals.
  • Effective directivity, source match, and load match allow for accurate measurement of device performance and characterization.
  • Accurate transmission and reflection measurements with magnitude and phase accuracy of up to 0.2dB/2°.
  • Trace stability and low trace noise (2mdB rms) ensure reliable and repeatable measurements.
  • Fast measurement time per point (42μs) allows for efficient testing and analysis.
  • Various calibration kits and cables are available as ordering options to further enhance measurement accuracy and flexibility.
  • Temperature stability of 0.01dB/℃ ensures accurate measurements even in varying temperature conditions.
  • External trigger input ports and reference input/output ports allow for synchronization with other devices and reference signals.
  • Robust design and system calibration intervals of 3 years ensure long-term reliability and accuracy.
Measurement range
Measurement range
Effective directivity ①
Effective directivity ①
Measurement accuracy - Accuracy of Transmission Measurements (magnitude / phase)
Measurement accuracy - Accuracy of Transmission Measurements (magnitude / phase)
Trace stability
Trace stability
Measurement speed
Measurement speed
Test port output
Test port output
Test port input
Test port input
Other parameters
Other parameters
- 50dB to +5dB
- 50dB to +5dB

0.1dB/1o

Match (W/O System Calibration)
Match (W/O System Calibration)

18dB

OS for Software
OS for Software

Windows 10, Windows 7

Match(W/O system error correction)
Match(W/O system error correction)

18 dB

Match (W/O System Calibration)
Match (W/O System Calibration)

18dB

Trace noise (IFBW=3kHz)
Trace noise (IFBW=3kHz)

2mdB rms

RBW Range
RBW Range

10Hz to 5MHz, (1-2-3-5-10 Sequence)

Maximum storage depth
Maximum storage depth

1Gbit

Match (W/O System Calibration)
Match (W/O System Calibration)

18 dB

Trace Noise(IFBW 3kHz)
Trace Noise(IFBW 3kHz)

5mdB rms

Display
Display

12.1 inch TFT color LCD,touch screen

Match(W/O system error correction)
Match(W/O system error correction)

18 dB

-15dB to 0dB
-15dB to 0dB

0.4dB/3°

Measurement time per point
Measurement time per point

42μs

+ 5dB to +15dB
+ 5dB to +15dB

0.2dB/2o

OS for Software
OS for Software

Windows 10, Windows 7

Effective directivity
Effective directivity

38~49dB

Sensitivity
Sensitivity

Low, Medium and High

Model
Model

BN100+

Effective directivity
Effective directivity

38~49dB

Operation system
Operation system

Based on Android

Frequency Range
Frequency Range

10MHz to 6GHz (upgradable to 300KHz)

Frequency Range
Frequency Range

9kHz to 6GHz

-15dB to 0dB
-15dB to 0dB

0.4dB/3o

Effective directivity
Effective directivity

38dB

External reference output
External reference output

SMA female; 10 MHz; 3 dBm ± 2 dB

Measuring Range
Measuring Range

Display average noise level to +20dBm

+5dB to +15dB
+5dB to +15dB

0.2dB/2°

+5 dB to +10 dB
+5 dB to +10 dB

0.2dB/2o

Frequency range
Frequency range

10MHz-6GHz (can upgrade to 1MHz - 6GHz)

Measurement time per point
Measurement time per point

42μs

Match (W/O System Calibration)
Match (W/O System Calibration)

18dB

Product model
Product model

BN1000

External trigger input port
External trigger input port

BNC female,input level range:0~+5 V

Product model
Product model

BN900-285: 2 ports 8.5GHz

BN900-465: 4 ports 6.5GHz

BN900-485: 4 ports 8.5GHz

-15dB to 0dB
-15dB to 0dB

0.4dB/3o

Trace noise (IFBW=3kHz)
Trace noise (IFBW=3kHz)

2mdB rms

Frequency Range
Frequency Range

1 MHz to 20 GHz

-50 dB to +5 dB
-50 dB to +5 dB

0.1dB/1o

Connectors
Connectors

RF output:N type,female,50 ΩUSB port:USB type-CPower interface:DC12V

Effective source match
Effective source match

35dB

RBW Accuracy
RBW Accuracy

RBW ≥ 1MHz,±10%

-25dB to -15dB
-25dB to -15dB

1.0dB/6o

Impedance
Impedance

50Ω

External reference input port
External reference input port

BNC female,10 MHz;2 dBm ± 2 dB

Digital Demodulation
Digital Demodulation

Digital signals

Frequency Step
Frequency Step

0.1Hz

Effective source match
Effective source match

35~41dB

Temperature stability
Temperature stability

0.01dB/℃

Power range (Option -70~+10dBm)
Power range (Option -70~+10dBm)

- 50dBm to + 5dBm(100kHz ~ 300kHz)- 50dBm to + 10dBm(300kHz ~ 7GHz)- 50dBm to + 8dBm(7GHz ~ 8.5GHz)

Temperature Stability
Temperature Stability

0.01dB/°C

-15dB to 0dB
-15dB to 0dB

0.4dB/3o

Impedance
Impedance

50Ω

Max input level
Max input level

+26dBm

Temperature Stability
Temperature Stability

0.03dB/°C

-50dB to +5dB
-50dB to +5dB

0.1dB/1°

Data format
Data format

I/Q two-way, 16bit

Operating temperature range
Operating temperature range

+5° C to +40° C

Power range
Power range

-20dBm to +10dBm

Frequency step
Frequency step

0.1Hz

Max input level
Max input level

+ 26dBm

Frequency Reference
Frequency Reference

Aging rate: ±1ppm

Power Supply Current
Power Supply Current

2A MAX

Impedance
Impedance

50Ω

-25dB to -15dB
-25dB to -15dB

1.0dB/6°

Power Supply Current
Power Supply Current

2A MAX

External trigger input port
External trigger input port

BNC female,input level range: 0~+5 V

Max input level
Max input level

+23 dBm

Source to receiver port switchover time
Source to receiver port switchover time

< 10ms

Power range (Option-70~+10dBm)
Power range (Option-70~+10dBm)

-50dBm to﹢10dBm(300kHz~7GHz)-50dBm to﹢8dBm(7GHz~8.5GHz)

Effective source match
Effective source match

35~41dB

-25dB to -15dB
-25dB to -15dB

1.0dB/6o

Input Attenuator Range
Input Attenuator Range

0-30dB, 1dB Step

Output Power Range
Output Power Range

-110 to +14dBm

Output Power Range
Output Power Range

-30 dBm to +10d Bm

Effective load match
Effective load match

37~49dB

Operation environment
Operation environment

Operation temperature: 0° C - 50° CStorage temperature: -20° C - 70° C

Frequency Readout Accuracy
Frequency Readout Accuracy

±( readout frequency * Frequency Reference + RBW mid-value + 0.5 *

Frequency-temperature Stability
Frequency-temperature Stability

±1ppm @0°C -50°C

Sweep points (IFBW 30kHz)
Sweep points (IFBW 30kHz)

512014011601

Effective load match
Effective load match

37dB

External reference input port
External reference input port

BNC female,10 MHz;2 dBm ± 2 dB

- 70dB to -50dB
- 70dB to -50dB

0.5dB/3o

Max input voltage
Max input voltage

+35V

Storage temperature range
Storage temperature range

-45° C to +55° C

Effective load match
Effective load match

37~49dB

-70dB to -50dB
-70dB to -50dB

0.5 dB/3o

-35dB to -25dB
-35dB to -25dB

3.0dB/20o

Test port connector
Test port connector

N-type, female

-70dB to -50dB
-70dB to -50dB

0.5dB/3°

-35dB to -25dB
-35dB to -25dB

3.0dB/20o

Power accuracy
Power accuracy

±1.5 dB

-35dB to -25dB
-35dB to -25dB

3.0dB/20°

Test port connector
Test port connector

N-type, female

Max input voltage
Max input voltage

+35 V

External reference output port
External reference output port

BNC female,10 MHz;2 dBm ± 2 dB

Power accuracy
Power accuracy

±1.5 dB

Connect interface
Connect interface

RF output: N-type, 50 ΩPC connect:USB type-CPower connect: DC12V

Power accuracy
Power accuracy

±1.5 dB

Max input voltage
Max input voltage

+ 35V

Connect interface
Connect interface

RF output: N-type, 50 ΩPC connect:USB type-CPower connect: DC12V

Test port connector
Test port connector

N-type, female

Frequency-temperature Stability
Frequency-temperature Stability

±1ppm @0 - 50°C

Maximum Safe Input Level
Maximum Safe Input Level

Sensitivity: +30dBm (Low)Sensitivity: 0dBm (Medium)Sensitivity: -20dBm (High)

Measurement parameters
Measurement parameters

S11 to S22

Working temperature
Working temperature

+5°C~+40°C

Noise level
Noise level

-107dBm/Hz (300kHz~10MHz) -124dBm/Hz (5GHz~6GHz) -120dBm/Hz (6GHz~8.5GHz)-123dBm/Hz (10MHz~5GHz)

Dimension
Dimension

197mm*93mm*61 mm

- 90dB to -70dB
- 90dB to -70dB

2.5dB/8o

Without calibration (300kHz~10MHz)
Without calibration (300kHz~10MHz)

51points: 13ms201points: 52ms401points: 104ms1601points: 413ms

Noise level
Noise level

- 97dBm/Hz(100kHz~300kHz)- 107dBm/Hz (300kHz~10MHz)- 123dBm/Hz (10MHz~5GHz)- 124dBm/Hz (5GHz~6GHz)- 120dBm/Hz (6GHz~8.5GHz)

Temperature
Temperature

Operating: 0° C to 50° CStorage: -20° C to 70° C

Power resolution
Power resolution

0.05dB

Initial Frequency Accuracy
Initial Frequency Accuracy

±0.5ppm

Temperature
Temperature

Opearting: 0° C to 50° CStorage: -20° C to 70° C

Power resolution
Power resolution

0.05dB

Operating humidity
Operating humidity

90% (25° C)

Number of test ports
Number of test ports

4

Number of test port
Number of test port

2

Reference Level Range
Reference Level Range

-140 dBm to +20dBm-190dBm to +70dBm (Ref level offset: ON)

External reference output port
External reference output port

BNC female,10 MHz;2 dBm ± 2 dB

Power resolution
Power resolution

0.05dB

-90dB to -70dB
-90dB to -70dB

2.5dB/8°

Noise level
Noise level

-120 dBm

Initial frequency accuracy
Initial frequency accuracy

±0.5ppm

-90dB to -70dB
-90dB to -70dB

2.5 dB/8o

Frequency Span Accuracy
Frequency Span Accuracy

±1%

Support communication standard signal type
Support communication standard signal type

GSM | WCDMA | TDD-LTE | FDD-LTE NB-IoT | LoRa | 5GNR

Measurement point per sweep
Measurement point per sweep

2 to 20001

Video output
Video output

DVI / HDMI

Power range
Power range

-110 - +14dBm

Number of test port
Number of test port

2/4

Full 2-port calibration(10MHz~6.5GHz)
Full 2-port calibration(10MHz~6.5GHz)

51points: 34ms201points: 73ms401points: 125ms1601points: 434ms

Frequency range
Frequency range

300KHz to 6.5GHz / 8.5GHz

Frequency range
Frequency range

300kHz to 6.5/8.5GHz

Operating atmospheric pressure
Operating atmospheric pressure

84 to 106.7 kPa

Sweep Time
Sweep Time

1.1ms to 1600s2.69ms to 1600s, zero span

Amplitude Accuracy
Amplitude Accuracy

±1.5dB (ATT set to 0 dB, input signal: -5 to -30 dBm; detector setto Positive,Sensitivity set to Low; RBW auto-coupled ,all otherSettings auto-coupled, 23±5°C , half hour warm-up required)

Power Range
Power Range

-110 to +14dBm

Dimension
Dimension

180×50×290(mm)

Dimension and weight
Dimension and weight

180×50×290(mm), 1.8kg

Storage temperature
Storage temperature

-20°C~+60°C

Frequency range
Frequency range

300kHz ~6.5GHz (option 265/465)300kHz ~8.5GHz (option 285/485)

Weight
Weight

0.9kg

Digital modulation type
Digital modulation type

BPSK | QPSK | OQPSK 8PSK | 16QAM | 32QAM 64QAM | 128QAM | 256QAM MSK | FSK

Dynamic Range
Dynamic Range

125 dB, typ. (1 MHz to 8 GHz)

120 dB, typ. (8 MHz to 12 GHz)

118 dB, typ.129dB (12 GHz to 18 GHz)

115 dB, typ.128dB (18 GHz to 20 GHz)

Power step
Power step

0.1dB

RBW Switching Uncertainty
RBW Switching Uncertainty

±0.3dB

Working humidity
Working humidity

90%(25°C)

Calibration interval
Calibration interval

3 years

USB port
USB port

8 ports(include 2 USB 3.0 ports)

Weight
Weight

1.8kg

Power Step
Power Step

0.1dB

Frequency accuracy
Frequency accuracy

±5ppm(option 0.05ppm)

Frequency accuracy
Frequency accuracy

±5ppm

Frequency accuracy
Frequency accuracy

±5ppm

Low Trace Noise
Low Trace Noise

8mdB rms @ IFBW=3 kHz

Frequency resolution
Frequency resolution

1Hz

Working pressure
Working pressure

84 to 106.7 kPa

Frequency resolution
Frequency resolution

1Hz

LAN port
LAN port

10/100/1000 Base T Ethernet,8-pin

Power Accuracy
Power Accuracy

±0.75dB@Lev>=-80dBm; ±1.5dB@Lev<-80dBm

Input Attenuator Uncertainty
Input Attenuator Uncertainty

±0.6dB

Power accuracy
Power accuracy

±0.75dB@Lev ≥ -80dBm,;±1.5dB@Lev<-80dBm

Frequency resolution
Frequency resolution

1Hz

Power supply
Power supply

110/220 ± 22 V (AC), 50 Hz

Measurement Speed
Measurement Speed

70 μs/point @  IFBW=500kHz

Measurement points
Measurement points

2~20,001

Harmonic
Harmonic

≤ -30dBc(+10dBm)

Number of measurement points
Number of measurement points

2 ~ 20,001

Harmonic
Harmonic

≤ -30dBc(+10dBm)

Number of measurement points
Number of measurement points

2 to 20001

Power consumption
Power consumption

18W

System calibration interval
System calibration interval

3 years

Working temperature
Working temperature

+5° C -I12 +40° C

Accuracy of Reference Level
Accuracy of Reference Level

Reference level: ≥ -60dBm, ±0.8dB

Support
Support

Standard VISA Protocol

Spurious
Spurious

≤ -50dBc

Measurement bandwidths
Measurement bandwidths

1Hz to 2MHz

Dimensions(W × H × D)
Dimensions(W × H × D)

175×65×292mm

Measurement bandwidths
Measurement bandwidths

1Hz to 100kHz

Nonharmonic
Nonharmonic

≤ -50dBc

Residual Response
Residual Response

-75dBm

Measurement bandwidth
Measurement bandwidth

1Hz to 2MHz

Power supply
Power supply

220 ± 22 V(AC),50 Hz

Storage temperature
Storage temperature

-20° C ~ +60° C

Dynamic range
Dynamic range

97 dB, typ. 115 dB (100kHz ~ 300kHz)112 dB, typ. 115 dB (300kHz ~ 10MHz)125 dB, typ. 130 dB (10MHz ~ 6GHz)124 dB, typ. 129 dB (6GHz ~ 7GHz)123 dB, typ. 128 dB (7GHz ~ 8.5GHz)

Phase noise
Phase noise

≤ -105dBc/Hz@10kHz(3GHz-6GHz); ≤ -109dBc/Hz@10kHz( ≤ 3GHz)

Weight
Weight

2.3 kg

Dynamic range(IFBW 10Hz)
Dynamic range(IFBW 10Hz)

112 dB,typ.115 dB (300kHz~10MHz) 125 dB,typ.130 dB (10MHz~6GHz) 124 dB,typ.129 dB (6GHz~7GHz) 123 dB,typ.128 dB (7GHz~8.5GHz)

Input-Related Response
Input-Related Response

9kHz to 700MHz - <-70dBc700MHz to 900MHz - <-46dBc900MHz to 1.3GHz - <-42dBc1.3GHz to 2.2GHz - <-46dBc2.2GHz to 2.7GHz - <-53dBc2.7GHz to 2.9GHz - <-42dBc2.9GHz to 3.3GHz - <-38dBc3.3GHz to 6GHz - <-53dBc

Dynamic range(IFBW 10Hz)
Dynamic range(IFBW 10Hz)

120dB

Phase Noise
Phase Noise

≤ -105dBc/Hz@10kHz(3-6GHz); ≤ -109dBc/Hz@10kHz( ≤ 3GHz)

Power consumption
Power consumption

65W

Working humidity
Working humidity

90% (25° C)

Working pressure
Working pressure

84 to 106.7 kPa

Measurement parameters
Measurement parameters

S11, S21, S12, S22

Second Harmonic Distortion
Second Harmonic Distortion

1.6GHz: 70dBc

Guarantee
Guarantee

1 year

Modulation bandwidth
Modulation bandwidth

20MHz(can upgrade to 100MHz)

Modulation bandwidth
Modulation bandwidth

20MHz(upgradable to 100MHz)

Dimension
Dimension

425 ×400×122 mm

Measurement parameters
Measurement parameters

S11, S21, S12, S22

Pulse modulation parameter
Pulse modulation parameter

Pulse period:10us-40s,Pulse width:10ns-40s

Weight
Weight

8.1kg

System calibration interval
System calibration interval

3 years

Third-Order Intercept (TOI)
Third-Order Intercept (TOI)

+15dBm (-10dBm tones, 1MHz apart, Sensitivity set to low,Ref set to -10 dBm)

Modulation Type
Modulation Type

I/Q, Pulse

Pulse modulation parameters
Pulse modulation parameters

pulse width: 10ns to 40s, repetition cycle: 10us to 40s

Power supply
Power supply

220 ± 22 V (AC), 50 Hz

General digital modulation type
General digital modulation type

BPSK、QPSK、OQPSK、8PSK、MSK、FSK、16QAM、32QAM、64QAM、128QAM、256QAM

General digital modulation type
General digital modulation type

BPSK, QPSK, OQPSK, 8PSK, MSK, FSK, 16QAM, 32QAM, 64QAM, 128QAM, 256QAM

P1dB
P1dB

+5dBm (nominal)

Analog modulation standard
Analog modulation standard

AM、FM、PM、DSB、USB、LSB

Phase Noise @1GHz
Phase Noise @1GHz

-95dBc/Hz, @10kHz (typically -98dBc/Hz)-123dBc/Hz, @1MHz (typically -125dBc/Hz)

Power consumption
Power consumption

130W

Analog modulation standard
Analog modulation standard

AM、FM、PM、DSB、USB、LSB

Dimension
Dimension

440 ×230×360 mm

Mobile communication standard
Mobile communication standard

GSM, EDGE, CDMA, TD-SCDMA, WCDMA, CDMA2000, TD-LTE, FDD-LTE, NB-IoT, LoRa, 5GNR

Mobile communication standard
Mobile communication standard

GSM/EDGE/CDMA/TD-SCDMA/WCDMA/CDMA2000/TD-LTE/FDD-LTE/NB-IoT/LoRa/5GNR

Support channel (LTE)
Support channel (LTE)

PSS、SSS、PSS、SSS、CSRS、PBCH、PCFICH、PHICH、PDCCH、PDSCH、PUSCH、PUCCH、PRACH and SRS

Supported Channel(LTE)
Supported Channel(LTE)

PSS, SSS, CSRS, PBCH, PCFICH, PHICH, PDCCH, PDSCH, PUSCH, PUCCH, PRACH and SRS

EVM
EVM

≤ 2%rms

EVM
EVM

≤ 1%rms (20MHz); ≤ 3.5%rms (100MHz)

Reference output
Reference output

10MHz,frequency error ±20Hz,power >0dBm

Frequency error
Frequency error

Better than ±10Hz

Phase error
Phase error

Better than ±3°

Waveform Quality
Waveform Quality

ρ >0.9999

Provide API
Provide API

Support secondary development (Open API)

TOI
TOI

+15dBm (-10dBm tones, 1MHz apart, Sensitivity set to low, Ref set to -10dBm)

Wave quality ρ
Wave quality ρ

>0.9999

API
API

Support secondary development(open API)

Frequently Asked Questions
What are the available options for the BN900 VNA?
What is the power range and accuracy of the BN900 VNA?
What is the calibration interval for the BN900 VNA?
What is the measurement speed of the BN900 VNA?
What is the measurement accuracy of the BN900 VNA?
What is the dynamic range of the BN900 VNA?
What is the measurement range of the BN900 VNA?
What type of connector is used for the test ports on the BN900 VNA?
How many test ports does the BN900 VNA have?
What is the frequency range of the BN900 VNA?

Want to become our distributors?

Join our distribution network now and become a part of our success story!